How to Safely Empty an AO Smith Water Heater
A loud popping rumble from the utility closet usually signals that heavy mineral sediment is trapped inside the water heater. Getting all that water out safely requires shutting off the power or gas, closing the cold water valve, and attaching a garden hose to the bottom drain spout while opening a hot faucet upstairs to break the suction.
The exact routine shifts slightly depending on how the tank runs and what the job requires. Electric units demand cutting the power at the breaker panel so bare heating parts do not burn out, while gas models just need the temperature knob turned to pilot. Flushing out loose grit takes only a few minutes, but replacing a part means letting the scalding water cool down before draining every gallon. Old mineral buildup can also choke the spout along the way. Here is the safest way to tackle the job from start to finish.
Shutting Off Power and Gas Before You Touch a Valve
Emptying your water heater always starts with cutting off the energy supply. If you leave the heat source on while the tank empties, you risk severe damage within seconds. Electric models contain heating elements that must stay submerged in water while hot. If electricity runs through those elements in an empty tank, they burn out almost immediately in a failure called dry firing. Gas models can overheat the metal tank bottom, crack the protective glass lining, and melt internal plastic parts.
For an electric A.O. Smith water heater, walk to your household electrical panel. Find the circuit breaker (the main power switch in your electrical panel) labeled for your water heater. It is usually a large double-pole switch rated for 30 amps. Push that switch firmly to the "Off" position. If your water heater has an external electrical disconnect switch mounted on the wall nearby, flip that lever down as well. Never rely on the water heater thermostat to turn off the power, because it can switch back on automatically when water cools.
For a gas model, you do not need to flip electrical switches unless you have a power-vent model that plugs into a wall outlet. Look at the lower front of the tank for the gas control valve (the small metal box with a temperature dial). Turn the top dial clockwise to the "Pilot" position if you plan to refill the tank the same day. Turn it all the way to "Off" if you are replacing the heater, swapping parts, or leaving the home empty for winter. Also turn the gas shut-off valve on the yellow or black iron gas pipe until the handle sits perpendicular to the pipe.
The water inside your tank sits between 120 and 140 degrees Fahrenheit. That is hot enough to cause third-degree burns within seconds if a hose slips or a valve leaks. Give the tank time to cool before draining it. You can speed this up by turning off the power the night before you plan to do the work. Alternatively, you can run a nearby hot water faucet for ten to fifteen minutes to draw cold water into the tank, bringing the overall temperature down to a lukewarm level.
Review this quick checklist before you connect any hoses or touch any water valves:
- The circuit breaker for electric models is turned completely off at the breaker box.
- The gas control knob is turned to Pilot or Off, and the gas supply line handle is closed.
- The water inside has cooled down so you do not risk scalding yourself or melting your hose.
- You have a clear, downward path for your drainage hose to reach a safe drain or outdoor spot.
- You have a standard garden hose, a flat-head screwdriver, and a bucket within arm reach.
Hooking Up the Drain Hose and Choosing Where the Water Goes
Once the tank is safe and cool, you need to set up a clean path for the water to leave. Near the bottom of your A.O. Smith tank, you will find the drain valve (the threaded spout near the bottom of the tank). Depending on the age and model of your unit, this spout will be made of brass or molded plastic. Brass spouts usually feature an oval turn handle, while plastic spouts often have a slot designed for a flat-head screwdriver. Treat plastic spouts gently, as aggressive twisting can strip the plastic or crack the valve body.
Grab a clean garden hose and inspect the rubber washer inside the female coupling. A missing or worn rubber washer will cause dirty water to pool around the base of your heater as soon as you open the spout. Screw the hose tightly onto the drain valve threads by hand. You can snug it slightly with a pair of slip-joint pliers, but do not overtighten it. If the valve is plastic, too much pressure can crack the threads right off the tank.
Next, route the other end of the hose to a location that can handle 40 to 80 gallons of water. The best choices are a basement floor drain, an open sump pump pit, or a laundry sink. If you run the hose outdoors, keep the end away from delicate flower beds, vegetable gardens, and small trees. Tank sediment contains concentrated minerals and scale that can leave white stains on stone patios or damage sensitive root systems. A sloped lawn, a gravel driveway, or a street gutter works well.
Water heaters rely on simple gravity to drain. If your drain hose has to travel uphill, water will stop flowing. Keep the entire hose run lower than the bottom of your water heater tank. If your water heater sits in a basement with no floor drain, gravity alone cannot lift the water up to a utility sink or an outdoor window. In that situation, you will need an electric transfer pump connected between two short hoses to pull water out of the tank and push it upward.
If you are draining a water heater located in an unheated garage or outbuilding during the winter, take extra care with freezing temperatures. Once the tank is empty, remaining drops inside the drain valve or surrounding plumbing can freeze and burst the brass fittings. In colder utility areas, many homeowners keep an electric heater for a garage with a thermostat running nearby to keep ambient air above freezing while maintenance is underway.
Opening the Drain Valve and Breaking Tank Suction
With your hose securely connected and routed to a drain, you are ready to empty the tank. The draining process requires two actions: letting water out through the bottom spout and letting fresh air into the top of the tank. If you do not let air in, the tank creates a vacuum lock (trapped suction that stops water from draining until air enters). It works just like holding your finger over the top of a drinking straw: the liquid inside stays trapped until you remove your finger.
- Close the incoming cold water: Locate the cold water shut-off (the handle on the top pipe that stops fresh water from entering the tank). If it is a ball valve with a long lever, turn the lever a quarter-turn until it forms a right angle to the pipe. If it is an older round wheel valve, turn it clockwise until it stops moving. Closing this valve prevents fresh water from continuously refilling the tank as you drain it.
- Open the drain valve: Turn the handle on the drain valve counterclockwise. If your valve has a slotted center instead of a handle, insert a large flat-head screwdriver and turn it counterclockwise. Keep an eye on the hose connection to make sure water is not dripping from the threads onto your floor.
- Break the internal suction: Walk to the nearest sink on an upper floor, or the sink closest to the water heater, and turn the hot water faucet handle fully on. Opening this faucet lets air flow backward through your plumbing pipes and into the top of the water heater tank. This releases the vacuum lock and allows water to flow rapidly out through the bottom garden hose.
- Alternative air intake method: If opening a sink faucet does not seem to break the suction, you can use the temperature and pressure relief valve (the safety valve mounted on the top or upper side of the tank, with a small brass lever). Gently lift the small metal test lever until it clicks open. You will hear air suck into the valve, and the water flow from the hose will immediately speed up. Only use this valve if you have tested it before, as very old safety valves can sometimes fail to seal shut again afterward.
- Monitor the water flow: A standard 50-gallon tank draining by gravity normally takes between 20 and 45 minutes to empty completely. Check the discharge end of the hose periodically to verify the flow has not stopped. The water might start clear, turn cloudy or milky brown as bottom minerals stir up, and finally slow to a gentle trickle as the tank finishes emptying.
When water stops flowing from the end of the hose, the tank is empty. If you are draining the tank to flush out sediment, you can leave the drain valve open, turn the cold water shut-off valve on for 30 seconds to wash the tank floor, and let that water drain out. If you are removing the heater or replacing an element, close the drain valve, disconnect your hose, and catch the last few tablespoons of residual water in a shallow bucket.
How to Clear Stubborn Sediment When Nothing Comes Out
One of the most common surprises when draining an A.O. Smith water heater is opening the drain valve only to find that zero water comes out. This happens frequently in homes with hard water. Over months and years of heating water, dissolved minerals like calcium and magnesium separate from the water and sink to the bottom. They form a thick layer of sand, chalky gravel, and large mineral flakes across the tank floor.
When you open the bottom spout, the sudden suction pulls that loose mineral gravel straight toward the opening. The debris jams tightly against the inside of the valve, creating a solid plug. Fortunately, you can easily clear this blockage without removing the valve or damaging the tank.
The fastest way to clear a sediment clog is to use incoming water pressure as a battering ram. Leave your garden hose connected to the drain valve and leave the drain valve open. Walk up to the top of the tank and open the cold water shut-off valve completely for about ten seconds. The full force of your municipal water pressure, typically 40 to 60 pounds per square inch, will blast down the internal dip tube directly onto the tank floor. This sudden rush breaks up the packed sediment and blows the plug straight through the open garden hose. You will hear a sudden rumble, followed by a dark blast of gravel and water exiting the hose. Close the top cold water valve again and let gravity finish draining the loosened water.
If blasting the tank with water pressure does not clear the jam, the clog is lodged directly inside the narrow neck of the drain valve. In this case, close the top cold water valve and close the bottom drain valve. Place a shallow pan or plastic tray under the valve to catch spills, and unscrew your garden hose. Insert a stiff, non-metallic probe or a straightened piece of heavy electrical wire into the drain valve opening. Gently push the wire inward while wiggling it until you feel it punch through the chalky crust. Water will immediately start gushing into your shallow pan. Quickly pull your wire out, screw your garden hose back on, and let the tank drain.
If you live in a manufactured home or specialized housing where mechanical closets have strict clearances, keeping plumbing free of sediment buildup is just as critical as maintaining appropriate clearance around your heater for mobile home utility closets. Mineral buildup in tight spaces strains both the tank and the shut-off valves, making routine flushes necessary to avoid messy plumbing leaks.
Refilling the Tank Safely Before Turning the Power Back On
Refilling your water heater properly is just as important as draining it correctly. The most critical rule of water heater maintenance is simple: never restore gas or electrical power to a tank that is not completely full of water. If you flip the circuit breaker back on while the tank is empty or partially filled, the upper heating element will heat up to extreme temperatures in open air and burn out in under thirty seconds. You will have to drain the unit all over again to replace the ruined element.
- Close the drain valve: Turn the drain valve clockwise until it is completely shut. If you are using a screwdriver-slot valve, tighten it snugly by hand, but do not force it past its stopping point. Remove the garden hose, shake out the remaining water, and put the hose away. Look closely at the spout opening to ensure no water is dripping.
- Keep an indoor hot faucet open: Go inside the house and turn on the hot water handle at a bathtub or sink. Leave it fully open. Right now, your water heater tank is full of air. As fresh water fills the tank from the bottom, it needs a clear pathway to push all that trapped air out of the plumbing system. Leaving an upstairs hot faucet open allows the air to escape easily.
- Open the cold water supply valve: Return to the water heater and slowly open the cold water shut-off handle at the top of the tank. Turn it until the handle aligns straight with the pipe. You will hear water rushing into the tank and filling the interior chamber.
- Bleed the trapped air from the pipes: Walk back to your open indoor faucet. For several minutes, you will hear loud hissing, sputtering, and coughing sounds coming from the faucet as compressed air escapes. The water will spit erratically and may look slightly discolored from loose pipe scale. This is completely normal.
- Confirm the tank is completely full: Keep watching the open faucet until the sputtering stops entirely and a smooth, continuous, solid stream of cold water flows from the spout. Let it run steadily for one full minute without a single air burp. This unbroken water stream is physical proof that the water level has risen to the very top of the tank and completely covered the upper heating elements.
- Close the indoor faucet and check for leaks: Turn off the indoor sink faucet. Return to the water heater and inspect the tank. Check around the bottom drain valve, the heating element access panels, and the top pipe connections. Now that the tank is under full household water pressure, look for any small drips or seepage.
- Restore the energy supply: Once you are certain the tank is completely full and leak-free, it is safe to turn the heat back on. For an electric unit, walk to your electrical panel and flip the circuit breaker back to the "On" position. For a gas unit, turn the gas control valve knob from Pilot back to "On", make sure the burner ignites, and adjust the temperature dial to 120 degrees Fahrenheit. It usually takes between 30 and 60 minutes for the water to heat back up to your normal temperature.
Frequently Asked Questions
How long does it take to completely empty an AO Smith water heater?
Draining a standard 40- or 50-gallon tank by gravity usually takes between 20 and 45 minutes. The total time depends on the length of your garden hose, the slope of the drain line, and how much mineral sediment is sitting on the bottom of the tank. If you open a hot water tap upstairs to let air in, the water will flow out significantly faster than if the tank remains vacuum-sealed.
Can I empty the tank without turning off the main water shut-off for my house?
Yes, you do not need to shut off water to your whole home. You only need to close the dedicated cold water shut-off handle located on the pipe directly above your water heater. Closing that single valve isolates the water heater from the rest of your plumbing, allowing your family to continue using cold water at sinks, toilets, and hose bibs while you drain the tank.
How often should an AO Smith water heater be drained or flushed?
Most manufacturers suggest draining or flushing your tank once a year to prevent mineral buildup and extend the lifespan of your unit. If you live in an area with particularly hard well water or high municipal mineral levels, flushing the tank every six months can help keep the bottom elements clean and stop rumbling sounds caused by trapped steam under scale deposits.
Related guides: does low point drain empty water heater.